DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D041116.1 | NSA/RWP/C1 - System problems | nsa915rwpwindconC1.a1 | Does not affect quality |
D050110.1 | NSA/RWP/C1 - Instrument problem, Data transfer problem | nsa915rwpwindconC1.a1 | Does not affect quality |
D050112.1 | NSA/C1 - Site-wide power failure | nsa915rwpwindconC1.a1 | Missing |
D070910.3 | NSA/RWP/C1 - Instrument problem | nsa915rwpwindconC1.a1 | Incorrect |
D090629.5 | NSA/RWP/C1 - Missing data blocks | nsa915rwpwindconC1.a1 | Missing |
D140303.4 | NSA/RWP/C1 - Phase shifter bad and upgrade of OS | nsa915rwpwindconC1.a1 | Missing |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/05/2004 | 0101 | 02/28/2005 | 0101 | Does not affect quality |
Subject: | NSA/RWP/C1 - System problems |
DataStreams: | nsa915rwpwindconC1.a1 |
Description: | RWP PC experienced repeated lock-ups during system operations. Various components were swapped out and the loggerboard configuration was modified. |
Measurements: | nsa915rwpwindconC1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/07/2003 | 0000 | 01/10/2005 | 0000 | Does not affect quality |
Subject: | NSA/RWP/C1 - Instrument problem, Data transfer problem |
DataStreams: | nsa915rwpwindconC1.a1 |
Description: | Problems with the coherent integration hardware resulted in repeated ingest failures when too many errors occurred. These cases involved occasions when there were no samples from a single axis (or more) during an averaging interval. If there were sufficient samples, the mean wind speed and direction were reported if normal data criteria were met. However, there were undoubtedly cases when only a few samples were obtained during an averaging interval. Thus the variability of the data is likely increased. The data are correct when reported. |
Measurements: | nsa915rwpwindconC1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/13/2004 | 1000 | 12/13/2004 | 2330 | Missing |
Subject: | NSA/C1 - Site-wide power failure |
DataStreams: | nsa915rwpwindconC1.a1 |
Description: | The Barrow facility experienced a site-wide power failure on 12/13. Power was restored to most instruments between 2250 and 2330 GMT. |
Measurements: | nsa915rwpwindconC1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/22/2007 | 2010 | 12/13/2007 | 2310 | Incorrect |
Subject: | NSA/RWP/C1 - Instrument problem |
DataStreams: | nsa915rwpwindconC1.a1 |
Description: | When data returned to ingest the windcon wind direction and wind speeds are not comparing well with the co-located sondes. Wind direction values are constant, with no changes. Problem is that the phase shifter wiring was bad when it was reinstalled. |
Measurements: | nsa915rwpwindconC1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/29/2009 | 1600 | 06/29/2006 | 1700 | Missing |
06/01/2009 | 1600 | 06/01/2009 | 1700 | Missing |
06/19/2009 | 1600 | 06/18/2009 | 1700 | Missing |
06/22/2009 | 1600 | 06/22/2009 | 1700 | Missing |
06/26/2009 | 1600 | 06/26/2009 | 1700 | Missing |
06/12/2009 | 1600 | 06/12/2009 | 1700 | Missing |
Subject: | NSA/RWP/C1 - Missing data blocks |
DataStreams: | nsa915rwpwindconC1.a1 |
Description: | The nsa915rwpC1 instrument was being re-booted at the end of the hour resulting in the unnecessary data loss. The time of re-boot was modified to the middle of the hour to avoid the 1-2 data loss period. |
Measurements: | nsa915rwpwindconC1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/23/2013 | 1500 | 10/29/2014 | 2110 | Missing |
Subject: | NSA/RWP/C1 - Phase shifter bad and upgrade of OS |
DataStreams: | nsa915rwpwindconC1.a1 |
Description: | No data available |
Measurements: | nsa915rwpwindconC1.a1:
|